Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 6 Months |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Pin# | Describe | ||
1-8(D0-D7) | Power set (16 Hexadecimal 0-FF, or 10 Hexadecimal 0-255) LSB (D0) corresponds PIN 1,MSB corresponds PIN8. | ||
- 00h (0): Min. output power. | |||
- FFh (255): Max. output power. | |||
-Without connection or don't use, equivalent to 00h. | |||
9 | Power on (Latch) rising edge is valid | ||
10-15,24 | Grounded | ||
16,21 | Laser source alarm status: | ||
Pin16 | Pin21 | Status | |
L | L | The laser temperature has exceeded the operating temperature range. | |
L | H | Normal status | |
H | H | MO abnormal | |
18 | Main Oscillator (MO) Switch Signal: | ||
- H level: MO open | |||
- L or not: MO OFF | |||
19 | Laser modulation input (Booster amplifier on / off input) | ||
- H level: Booster open | |||
- L or not: Booster off | |||
20 | Pulse repetition frequency (synchronous) input is square wave. | ||
The specifications refer to the operating PRR range. The allowable duty cycle is 0.1 to 0.9. | |||
22 | Guide laser (red diode) on / off input | ||
- H level: On | |||
- L or not: off | |||
23 | Emergency stop input | ||
- H level: OK (normal operation) | |||
- L level or not: STOP (laser auto off) |
PIN | Signal Form | Signal Name | Description |
1 | Output | CLK- | Clock signal to D/A |
2 | Output | SYNC- | Synchronization signal to D/A |
3 | Output | Chan X- | Channel X data stream to D/A |
4 | Output | Chan Y- | Channel Y data stream to D/A |
5 .7.8.18.20.21 | Not connected | NC | NC |
6 | Output | STATUS- | |
9.10.22 | Output | +15V | +15V power to D/A |
11.23.24 | Output | GND | Ground |
12.13.25 | Output | -15V | -15V power to D/A |
14 | Output | CLK+ | Clock signal to D/A |
15 | Output | SYNC+ | Synchronization signal to D/A |
16 | Output | Chan X+ | Channel X data stream to D/A |
17 | Output | Chan Y+ | Channel Y data stream to D/A |
19 | Output | STATUS+ |